Lung CAD shows promise as concurrent reader
Computer-aided detection (CAD) technology can yield favorable results in detecting lung nodules when used concurrently during the reading process, according to research from Kobe University Graduate School of Medicine in Japan.
“In this study of lung nodule detection at MDCT by the use of our prototype CAD system, the sensitivity, false-positive rate, and reading time of chest radiologists when using the system as concurrent reader were similar to those when using the system as a second reader,” said Dr. Sumiaki Matsumoto, Ph.D.
While many studies have found CAD to improve the sensitivity of detecting lung nodules when used as a second reader, the technology might be better integrated into clinical workflow if it could be used at the same time the radiologist views the CT images, Matsumoto said. He presented the research during a session at the 2008 RSNA meeting in Chicago.
The study team sought to compare the performance of chest radiologists in lung nodule detection on MDCT scans when using a prototype CAD system first as a concurrent reader and then as a second reader.
Sixty MDCT datasets were included in the study, produced from either an Aquilion 16 or Aquilion 64 CT scanner (Toshiba Medical Systems, Tochigi, Japan) at 120 kVp, 150 mAs, 15 x 0.5 mm or 64 x 0.5 mm, and 0.94 or 0.84 beam pitch. Images were reconstructed with a 1-mm slice thickness and interval using a lung kernel.
The 60 studies contained 122 noncalcified nodules 4 mm or larger (as determined by a separate chest radiologist) and were read independently by three chest radiologists with 18, seven, and five years of experience, respectively. The radiologists first read the studies with CAD as a concurrent reader; four to six weeks later, the radiologists then read the same exams using CAD as a second reader.
The radiologists were asked to rate their findings for confidence level (0 = normal, 1 = definitely non-nodule but not normal, 2 = probably non-nodule, 3 = probably nodule, and 4 = definitely nodule) and follow-up action (0 = no need to follow up, 1 = follow-up at 12 months, 2 = follow-up at six months, and 3 = follow-up at three months at least or further workup and/or biopsy), according to Matsumoto. Findings with a confidence of 3 to 4 and follow-up of 1 to 3 were considered positive.
Sensitivity
|
The sensitivity differences were not statistically significant for any radiologist (p = 0.33, p = 0.75, and p = 0.77).
As for false positives, radiologist 1 had a mean of 0.7 with CAD as a concurrent reader and 0.88 with CAD as a second reader (p = 0.17). Radiologist 2 had a mean of 1.5 false positives with CAD as a concurrent reader and 1.47 with CAD as a second reader (p = 1.47), and radiologist 3 had a mean of 0.25 false positives with CAD as a concurrent reader and 0.3 with CAD as a second reader (p = 0.67).
The researchers also evaluated the reading time for each radiologist for both CAD approaches.
Reading time (seconds)
|
The differences were not statistically significant (p = 0.48, p = 0.41, and p = 0.43).
“Comparable results were found in sensitivity, false positives, and reading time,” Matsumoto said.
By Erik L. Ridley
AuntMinnie.com staff writer
January 30, 2009
If you enjoyed this post, make sure you subscribe to my RSS feed!
Recent Entries
- Nuclear breast imaging may have greater cancer risks
- 3-D In Angiography, New Imaging Software From Siemens Simplifies Workflow For Minimally Invasive Heart Valve Implantation
- Constipated kids don’t need abdominal x-rays
- Cardiac model favors treadmill then CTA for low-risk patients
- Certain Conventional Ultrasound Characteristics May Eliminate The Need For Some Minimally-Invasive Thyroid Biopsies
- Breast MRI improves cancer staging for newly diagnosed women
- Skeletal PET gains support for pediatric bone scans
- Radiation ups risk of breast cancer in young women
- One abdominopelvic CT scan may be enough for pediatric trauma
- Does mammogram row signal time for policy shift?